Click here for pdf version.

Compatibility Adjustment

Note: Set compatibility before removing battery pull tabs.

Remove backplate. Turn compatibility dial with flathead screwdriver to coordinating security system. See Figure A.

Security System
Setting
Honeywell 0
2GIG 1
Qolsys | Interlogix 2
DSC 3
Bosch 4

Installation Instructions

Choose Installation Location

Mounting Location: The sensor should be mounted between 6.5ft and 8.5ft above the floor. All protected glass must be within a clear line of sight of the sensor and within the 20ft max range.

Secure To Surface

Note: For UL/cUL listed the device shall be secured using the provided mounting screws.

Detach Back Plate

Remove back plate by prying top notch with a flathead screwdriver. See Figure B.

Remove Battery Tabs

See Figure C. Note: Detector LED will flash rapidly for 5 minutes as part of initial power up sequence.

Replace Back Plate

Learn Into Panel

    1. Place your panel in AUTO LEARN mode.
    2. Open and close the case to TAMPER the device.
    3. Customize name and settings as desired and touch ADD.

Testing Mode

Note: To properly test the Versa Glass Break, a glass break simulator is required.

Sensitivity: Two dip switches allow you to customize the sensitivity and detection range of the Versa Glass. The factory default is set to MAX. Please refer to the table below to customize the sensitivity.

Switches: Set dip switches based on desired detection range.

 Sensitivity Detection Range 1 2
Maximum 20 feet OFF
OFF
Medium 13 feet
OFF
ON
Low 8 feet
ON
OFF
Lowest 5 feet
ON
ON


Testing Mode

Test Mode: Place the sensor in test mode by disconnecting the batteries for 30 seconds then reconnecting. Test mode is active for 5 minutes upon the sensor powering on. The LED blinks every second when the sensor is in test mode. The Versa Glass does not transmit an RF Signal while it is in test mode. Please refer to the table below for the LED indicator guide. The sensor will exit test mode after the first 5 minutes of power up.

 Condition Red LED
Initial Power Up Rapid Flash For 5 Minutes
Test Mode Flash Once Per Second
Test Mode, Alarm Event Rapid Flash For 2 Seconds
Normal Mode, Alarm Event Solid For 5 Seconds
Low Battery Flash Once Every 30 Seconds


Testing Mode

    1. Set the switches to the TEST and MANUAL modes. See Figure D.
    2. Position the glass break simulator near the protected glass and point the speaker directly at the Versa Glass. See Figure E. Important: If window coverings are present, close them fully and hold the glass break simulator behind the window coverings for testing.
    3. Press the red start button and the glass break simulator will generate a burst of glass break audio. If the LED on the Versa Glass sensor flashes rapidly for 2 seconds an alarm event has been detected and the range is acceptable for audio. If the LED does not flash, position the Versa Glass closer to the glass and try again.
Note: The Versa Glass does not transmit an RF Signal while it is in Test Mode.

Note: Serial numbers are located under battery. See Figure F.

FCC Notice

This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference that may be received, including interference that may cause undesired operation.¹

Changes or modifications not expressly approved by Versa Wireless Inc. can void the user’s authority to operate the equipment. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

 

 

¹ For UL compliance the units are for residential use only.