{"product_id":"plug-od-zw","title":"PLUG-OD-ZW","description":"\u003cdiv class=\"vw-pdp\"\u003e\n\u003cdiv class=\"vw-tabs\"\u003e\n\u003cinput class=\"vw-tabinput\" type=\"radio\" name=\"vw-tab\" id=\"vw-t1\" checked\u003e \u003cinput class=\"vw-tabinput\" type=\"radio\" name=\"vw-tab\" id=\"vw-t2\"\u003e \u003cinput class=\"vw-tabinput\" type=\"radio\" name=\"vw-tab\" id=\"vw-t3\"\u003e\n\u003cdiv class=\"vw-tabbar\" role=\"tablist\" aria-label=\"Product information\"\u003e\n\u003clabel class=\"vw-tab\" for=\"vw-t1\"\u003eDescription\u003c\/label\u003e \u003clabel class=\"vw-tab\" for=\"vw-t2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"vw-tab\" for=\"vw-t3\"\u003eCompatible Controllers\u003c\/label\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"vw-panel vw-p1\"\u003e\n\u003cp\u003eThe Versa Wireless PLUG-OD-ZW is a \u003cstrong\u003eZ-Wave outdoor smart plug\u003c\/strong\u003e built on Z-Wave 800 Series Long Range. It is an IP65 plug-in module, rated for outdoor use, with \u003cstrong\u003etwo grounded outlets you can switch separately\u003c\/strong\u003e. It hangs from an outdoor receptacle and needs no wiring, so you get a switched Z-Wave outdoor outlet without changing anything in the wall. Control each outlet from your hub, or use the button on the unit. On Long Range it reaches up to \u003ca href=\"https:\/\/versawireless.com\/blogs\/insight\/z-wave-800-long-range-explained\" style=\"color: #1565c0 !important;\"\u003e1300 ft straight to the controller\u003c\/a\u003e, or 330 ft (100 m) per hop on classic mesh.\u003c\/p\u003e\n\u003cp\u003eTwo outlets, one device. Each outlet is a separate Z-Wave endpoint, so your hub sees two switches under a single paired device. Run the string lights on one and the landscape lighting on the other, on separate schedules. It also means one outdoor plug uses \u003cstrong\u003eone device slot on your controller instead of two\u003c\/strong\u003e, which matters on panels that cap how many Z-Wave devices they hold.\u003c\/p\u003e\n\u003cp\u003eThe enclosure is IP65 rated and the plug runs from -4 to 122 deg F, so it stays outside through the season. Install it the way the enclosure was designed to work. Plug it into a covered Class A GFCI weatherproof receptacle, on a circuit with 20 A branch-circuit overcurrent protection. Then \u003cstrong\u003ehang it vertically with the outlets facing downward\u003c\/strong\u003e, so water runs off rather than in. Mount it more than 1 ft above the ground.\u003c\/p\u003e\n\u003cp\u003eThe ETL listing rates it at \u003cstrong\u003e15 A general purpose, 15 A resistive, 1250 W incandescent, 1250 W tungsten, or a 1\/2 HP motor\u003c\/strong\u003e. Those are the limits for each outlet on its own and for both outlets together. The motor rating is what lets it run a pump or a fan, not only lights.\u003c\/p\u003e\n\u003cp\u003eSetup is a QR scan. Scan the Z-Wave QR code on the unit and a SmartStart hub adds it on its own with S2 encryption. The DSK code is printed on the packaging box, so keep the box until the plug is paired. Seven settings cover the indicator, its brightness, and what happens after a power cut. Four of them are the auto on and auto off timers, one pair per outlet. See \u003ca href=\"https:\/\/versawireless.com\/blogs\/insight\/z-wave-configuration-parameters-association-groups\" style=\"color: #1565c0 !important;\"\u003eZ-Wave configuration parameters and association groups\u003c\/a\u003e. Full specifications are in the Specifications tab, and the step-by-step is in the \u003ca href=\"https:\/\/versawireless.com\/blogs\/installation-manuals\/plug-od-zw-installation-manual\" style=\"color: #1565c0 !important;\"\u003ePLUG-OD-ZW installation manual\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"vw-kf\" style=\"font-size: 17px; line-height: 24px; font-weight: 600; margin: 26px 0 8px; color: #081f3f !important;\"\u003eKey features\u003c\/h2\u003e\n\u003cul class=\"vw-list\"\u003e\n\u003cli\u003eZ-Wave 800 Long Range. Up to 1300 ft direct-to-controller (LR) - 330 ft (100 m) per hop (mesh)\u003c\/li\u003e\n\u003cli\u003eTwo grounded outdoor outlets. Each one is switched on its own Z-Wave endpoint\u003c\/li\u003e\n\u003cli\u003eIP65 enclosure rated for outdoor use. Runs from -4 to 122 deg F (-20 to 50 deg C)\u003c\/li\u003e\n\u003cli\u003e15 A general purpose, 15 A resistive, 1250 W incandescent, 1250 W tungsten, 1\/2 HP motor at 125 VAC. Those limits apply to each outlet and to both together\u003c\/li\u003e\n\u003cli\u003eSmartStart pairing with S2 encryption. Scan the Z-Wave QR code on the unit\u003c\/li\u003e\n\u003cli\u003eTimers held in the plug. An auto turn-off and an auto turn-on for each outlet, 1 to 65535 minutes\u003c\/li\u003e\n\u003cli\u003ePower-failure memory. Each outlet comes back off, on, or to its last state\u003c\/li\u003e\n\u003cli\u003eAdjustable indicator brightness. The indicator mode changes from the button too\u003c\/li\u003e\n\u003cli\u003eBuilt-in repeater on the classic mesh. Extends coverage for other mains-powered devices; in Long Range the plug links straight to the controller instead\u003c\/li\u003e\n\u003cli\u003eWorks with any Z-Wave certified hub, older or newer generation\u003c\/li\u003e\n\u003cli\u003e5.5 in. x 2.2 in. x 4.5 in. housing on a 6.1 in. cord\u003c\/li\u003e\n\u003cli\u003eUS 125 VAC | FCC Part 15 Class B | ETL Listed (c-US) - conforms to UL 60730-1:2016, certified to CSA E60730-1:2015\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"vw-panel vw-p2\"\u003e\n\u003csection class=\"versa-spec-table\"\u003e\n\u003ch2 id=\"plugodzw-specs-heading\" style=\"font-size: 19px; line-height: 26px; font-weight: 600; margin: 0 0 14px; color: #081f3f !important;\"\u003ePLUG-OD-ZW Specifications\u003c\/h2\u003e\n\u003cp class=\"versa-spec-sub\"\u003eZ-Wave 800 LR Outdoor Dual-Outlet Smart Plug\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003eWireless \u0026amp; Z-Wave\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eProtocol\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\u003cstrong\u003eZ-Wave 800 Series with Long Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e908.42 \/ 916 MHz mesh - 912 \/ 920 MHz LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eRange\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003eUp to 1300 ft direct-to-controller (LR)\u003c\/strong\u003e - 330 ft (100 m) per hop (mesh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSignal Repeater\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eBuilt-in on the classic mesh - the plug is always powered, so it repeats for other devices. Added in Long Range mode it links straight to the controller instead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eController Compatibility\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eAny Z-Wave certified controller. Long Range requires an 800 Series controller with Long Range enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eNetwork Interoperability\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eWorks with any Z-Wave certified network. Older and newer Z-Wave devices work together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eZ-Wave Platform\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eZ-Wave 800 Series with Long Range, SDK 7.24.1 - background at the \u003ca href=\"https:\/\/z-wavealliance.org\/\" rel=\"nofollow noopener\" style=\"color: #1565c0 !important;\" target=\"_blank\"\u003eZ-Wave Alliance\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDevice Class\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eGeneric SWITCH BINARY | Specific NOT USED | Role Always On Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eEndpoints\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e2 - one per outlet\u003c\/strong\u003e (left and right), reported over Multi Channel. Your hub sees two switches under one paired device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDevice IDs\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eManufacturer 0x0464 | Product Type 0xAC01 | Product ID 0x0097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eVersion\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eV1.0 - Z-Wave SDK 7.24.1, Z-Wave version 8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003ePairing \u0026amp; Security\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSmartStart\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eYes - scan the Z-Wave QR code on the unit. The DSK code is printed on the packaging box, so keep it until the plug is paired. Long Range needs SmartStart and an LR-enabled hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSecurity\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eS2 security. Use a controller that supports S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eManual Inclusion\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003ePress the button 3x quickly - blue LED flashes, green 2 s = added. Auto-add: the LED starts blinking within 30 seconds of first plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eManual Exclusion\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003ePress the button 3x quickly - purple LED flashes, then green 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eAssociation Group 1\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eLifeline - up to 5 devices, Binary Switch Report. Most controllers set this automatically during inclusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eAssociation Group 2\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eLeft outlet - Basic Set, up to 5 devices, triggered by button control of the local load. Association is available through the gateway only. The group ID for the right outlet is pending factory confirmation - see the installation manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFactory Reset\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eClick the button 2x quickly, then hold at least 10 seconds. The light flashes once when the reset succeeds. Removing the plug from your hub also resets it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003ePower \u0026amp; Load\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e125 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eMaximum Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e15 A total between the 2 outlets\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eGeneral Purpose Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e15 A\u003c\/strong\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eResistive Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e15 A\u003c\/strong\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eIncandescent Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e1250 W\u003c\/strong\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eTungsten Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e1250 W\u003c\/strong\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eMotor Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e1\/2 HP max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eRating Basis\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003ePer the ETL listing, each load rating above is the limit for \u003cstrong\u003eeach outlet on its own and for both outlets together\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eOutlets\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e2 switched, grounded 3-wire (NEMA 5-15R), controlled independently\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eReceptacle\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003eCovered Class A GFCI weatherproof receptacle on a 20 A protected branch circuit\u003c\/strong\u003e - see the safety note below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eCord\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e6.1 in. (155 mm), grounded 3-prong plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003ePower-Fail Restore\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eParameter 6 - 0 = off, 1 = on, 2 = the state prior to the power failure (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFirst Power-Up\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eA plug that has never joined a network powers up with both outlets off and the blue LED on. A plug already on a network returns each outlet to its last state with a soft start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003eFunction \u0026amp; Indicators\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDevice Type\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eOutdoor plug-in on\/off module, 2 outlets (binary switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eButton\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eOn the unit. 1x = left outlet on \/ off | 2x = right outlet on \/ off | hold 3 s = all outlets on \/ off | 3x = add or remove | 2x then hold 10 s = factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eButton Parameter Stepping\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e6x cycles parameter 1 (LED indicator) | 8x cycles parameter 7 (indicator brightness) | 10x cycles parameter 6 (state after power failure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eTimers\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eAuto turn-off for each outlet (parameters 2 and 3) and auto turn-on for each outlet (parameters 4 and 5). Minutes 1-65535. 0=disabled. Set them from your controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eLED Indicator Mode\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eParameter 1 - four modes, printed in the installation manual as 0 = Relay (default), 1 = pos, 2 = ON, 3 = OFF. Step it with 6 taps of the button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eIndicator Brightness\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eParameter 7 - 0 = Bright, 1 = Medium, 2 = Low (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eConfiguration Parameters\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e7 total - 1 through 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eLED Indicator\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eBlue steady = an outlet is on, with the behaviour set by parameter 1; also lit on first power-up, before the plug joins a network | blue off = both outlets off | blue flashing = add in progress | purple flashing = remove in progress | green 2 s = add or remove succeeded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003ePhysical \u0026amp; Operating Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e5.5 in. x 2.2 in. x 4.5 in. (140 mm x 56 mm x 115 mm) housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e-4 to 122 deg F (-20 to 50 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003eIP65 rated for outdoor use\u003c\/strong\u003e, polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eUse\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eIndoor \/ outdoor. Hang vertically with the outlets facing downward, more than 1 ft above the ground surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eMarket\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eUS (125 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eOrigin\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eMade in Vietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e2 years from the original date of consumer purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003eCertifications \u0026amp; Compliance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSafety Listing\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003ca href=\"https:\/\/www.intertek.com\/product-certification-marks\/etl\/\" rel=\"nofollow noopener\" style=\"color: #1565c0 !important;\" target=\"_blank\"\u003eETL Listed by Intertek\u003c\/a\u003e, c-US mark - conforms to UL 60730-1:2016 and certified to CSA E60730-1:2015 (automatic electrical controls) | Intertek control no. 5030071\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFCC\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eFCC Part 15 Class B | FCC ID: 2AD9XPLUG-OD-ZW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eRF Exposure\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eComplies with FCC uncontrolled-environment limits - install and operate with 20 cm minimum separation from any person\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"versa-foot\"\u003eRead all instructions before use. Plug the unit only into a covered Class A GFCI-protected weatherproof receptacle, on a circuit with 20 A branch-circuit overcurrent protection. The cover must close completely over the plug and cord; if one is not provided, contact a qualified electrician. Do not use an extension cord. Hang the unit vertically with the outlets facing downward, more than 1 ft above the ground surface. Do not install or use within 10 ft of a pool. Do not use in a bathroom. Do not exceed 15 A total between the two outlets. Do not use this plug to control medical or life-support equipment, electric heaters, or any device that could become hazardous if switched unattended. Do not include appliance-controlling devices in groups or scenes. Schedules, automations, or network errors may cycle a device unintentionally, so use extreme caution with appliances. Install per the National Electrical Code (NFPA 70) and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. Where required by code, installation must be performed by a qualified, licensed electrician. If unsure, consult an electrician.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"vw-panel vw-p3\"\u003e\n\u003cp\u003eLong Range is where the category is heading: \u003ca href=\"https:\/\/versawireless.com\/blogs\/insight\/z-wave-long-range-adoption-tracker\" style=\"color: #1565c0 !important;\"\u003emost new Z-Wave certifications are Long Range\u003c\/a\u003e. The PLUG-OD-ZW works with any Z-Wave certified controller, so it drops into a Z-Wave smart home network you already run. That includes 2GIG EDGE, Qolsys IQ, SmartThings, Hubitat, Ring Alarm Pro, and Home Assistant with a Z-Wave 800 controller. On a classic mesh network every mains-powered device acts as a repeater, and this plug is one of them.\u003c\/p\u003e\n\u003cp\u003eAn outdoor plug is often the device that sits furthest from the hub, which is why the pairing mode matters here more than indoors. To use Long Range, pair it to an 800 Series Long Range controller with SmartStart. Scan the Z-Wave QR code on the unit using your controller app. The plug joins on its own with S2 encryption. To join a classic mesh instead, set the controller to add a device and press the button three times quickly.\u003c\/p\u003e\n\u003cp class=\"vw-related\"\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e the PLUG-OD-ZW installation manual ships in the box and is published as a web page: \u003ca href=\"https:\/\/versawireless.com\/blogs\/installation-manuals\/plug-od-zw-installation-manual\" style=\"color: #1565c0 !important;\"\u003ePLUG-OD-ZW Installation Manual and Setup Guide\u003c\/a\u003e. The rest of the line is in the \u003ca href=\"https:\/\/versawireless.com\/blogs\/installation-manuals\" style=\"color: #1565c0 !important;\"\u003eVersa installation manuals and datasheets\u003c\/a\u003e library. The FCC ID printed on the unit is 2AD9XPLUG-OD-ZW.\u003c\/p\u003e\n\u003cp class=\"vw-related\"\u003e\u003cstrong\u003eAlso in the Versa Z-Wave 800 line:\u003c\/strong\u003e the \u003ca href=\"https:\/\/versawireless.com\/products\/plug-zw\" style=\"color: #1565c0 !important;\"\u003ePLUG-ZW indoor smart plug\u003c\/a\u003e switches a lamp or appliance on a standard indoor outlet. The \u003ca href=\"https:\/\/versawireless.com\/products\/lamp-zw2\" style=\"color: #1565c0 !important;\"\u003eLAMP-ZW2 plug-in dimmer\u003c\/a\u003e sets a brightness level for a lamp instead. The \u003ca href=\"https:\/\/versawireless.com\/products\/switch-zw\" style=\"color: #1565c0 !important;\"\u003eSWITCH-ZW in-wall light switch\u003c\/a\u003e and the \u003ca href=\"https:\/\/versawireless.com\/products\/dim-zw\" style=\"color: #1565c0 !important;\"\u003eDIM-ZW in-wall dimmer switch\u003c\/a\u003e cover hardwired circuits.\u003c\/p\u003e\n\u003csection class=\"vw-faq\" style=\"margin-top: 32px;\"\u003e\n\u003ch2 id=\"plugodzw-faq-heading\" style=\"font-size: 19px; line-height: 26px; font-weight: 600; margin: 0 0 14px; color: #081f3f !important;\"\u003ePLUG-OD-ZW questions installers ask\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eCan I control each outlet separately?\u003c\/h3\u003e\n\u003cp\u003eYes. That is the main thing this plug does. Each outlet is its own Z-Wave endpoint, so your hub lists two switches and you turn each one on and off independently.\u003c\/p\u003e\n\u003cp\u003eThe button does the same thing at the unit. Tap it once for the left outlet and twice for the right. Hold it for three seconds to switch both together.\u003c\/p\u003e\n\u003cp\u003eEach outlet also gets its own timers, so one can run on a schedule while the other stays on. The load ratings apply to each outlet on its own and to both outlets together.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eDoes the PLUG-OD-ZW need a hub?\u003c\/h3\u003e\n\u003cp\u003eYes, for Z-Wave control. The PLUG-OD-ZW is a Z-Wave plug, so a Z-Wave certified controller is what gives you remote control of the outlets. A hub is also what puts them in a scene or on a schedule.\u003c\/p\u003e\n\u003cp\u003eAny Z-Wave certified hub works. Long Range mode needs an 800 Series controller with Long Range switched on.\u003c\/p\u003e\n\u003cp\u003eThe button works with or without a hub, so the plug still switches by hand if the network is down.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eHow do I add, pair, or reset the PLUG-OD-ZW?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo add it by QR code:\u003c\/strong\u003e scan the Z-Wave QR code on the unit with your controller app, then plug it in. It joins on its own with S2 encryption. This is also how it joins in Long Range mode, on an 800 Series controller with Long Range enabled.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo add it by button:\u003c\/strong\u003e set the controller to add a device, then press the button three times quickly. The LED flashes blue, then lights green for two seconds when it is added. This route joins the classic mesh.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo remove it:\u003c\/strong\u003e set the controller to remove a device, then press the button three times quickly. The LED flashes purple, then green for two seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo factory reset it:\u003c\/strong\u003e click the button twice quickly, then hold for at least ten seconds. The light flashes once when the reset succeeds. Use this only if your primary controller is missing or will not respond. Removing the plug from your hub also resets it.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat kind of outlet does the PLUG-OD-ZW need outdoors?\u003c\/h3\u003e\n\u003cp\u003eA covered Class A GFCI weatherproof receptacle, on a circuit with 20 A branch-circuit overcurrent protection. The cover has to close completely over the plug and the cord. If the receptacle does not have one, an electrician can fit it.\u003c\/p\u003e\n\u003cp\u003eHang the unit vertically with the outlets facing downward. That is what keeps water out of the enclosure, and it is how the IP65 rating is meant to be used. Keep it more than 1 ft above the ground surface.\u003c\/p\u003e\n\u003cp\u003ePlug it straight into the receptacle. The safety note at the foot of the Specifications tab has the full list, including the distances to keep from a pool.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat can I plug into the PLUG-OD-ZW?\u003c\/h3\u003e\n\u003cp\u003eAnything inside its ETL-listed ratings at 125 VAC. That is 15 A general purpose, 15 A resistive, 1250 W incandescent, 1250 W tungsten, or a 1\/2 HP motor. Each of those is the limit for one outlet on its own and for both outlets together.\u003c\/p\u003e\n\u003cp\u003eThe motor rating is the one that widens what this plug is for. A 1\/2 HP limit covers a pond or fountain pump, a fan, or a small outdoor tool, alongside the string lights and landscape lighting an outdoor plug usually runs.\u003c\/p\u003e\n\u003cp\u003eRead the safety note at the foot of the Specifications tab before you pick a load. It lists what Versa warns against switching remotely.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eHow cold can the PLUG-OD-ZW get?\u003c\/h3\u003e\n\u003cp\u003eIt runs from -4 to 122 deg F, which is -20 to 50 deg C. That covers a normal winter in most of the country and a hot roof or patio in summer.\u003c\/p\u003e\n\u003cp\u003eThe housing is polycarbonate and the enclosure is IP65 rated, so rain and dust are what it was built for. It is made to stay outside rather than come in between uses.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eHow far does the PLUG-OD-ZW reach on Z-Wave Long Range?\u003c\/h3\u003e\n\u003cp\u003eUp to 1300 ft direct-to-controller on Long Range, and 330 ft (100 m) per hop on classic mesh. The two numbers measure different things. On Long Range the plug talks straight to the hub, so 1300 ft is one direct link with nothing in between. On mesh, 330 ft is the length of a single hop, and the network reaches further by chaining hops through other mains-powered devices.\u003c\/p\u003e\n\u003cp\u003eThis is the reach that makes a Z-Wave outdoor plug practical at the end of a driveway, on a detached garage, at a barn, or across a large yard. Those are the spots where a mesh signal has to leave the house and usually runs out.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eDoes the PLUG-OD-ZW work as a Z-Wave repeater?\u003c\/h3\u003e\n\u003cp\u003eOn a classic mesh, yes. The plug is always powered, so it passes traffic for other devices and strengthens coverage around it. An outdoor plug is a useful place for that, because it sits between the house and anything further out.\u003c\/p\u003e\n\u003cp\u003eThere is a catch worth knowing before you pair it. Long Range is a direct link between the device and the controller. A plug added in Long Range mode talks only to the hub, so it repeats for nothing while it is in that mode.\u003c\/p\u003e\n\u003cp\u003ePick the mode by the job. Scan the QR code to a Long Range hub when you need reach. Add it by button to the classic mesh when you want a repeater.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eCan each outlet run on a timer?\u003c\/h3\u003e\n\u003cp\u003eYes, and the timers live in the plug rather than in the hub. Each outlet has an auto turn-off delay and an auto turn-on delay of its own. Parameters 2 and 3 are the off delays for the left and right outlet. Parameters 4 and 5 are the on delays.\u003c\/p\u003e\n\u003cp\u003eAll four take 1 to 65535 minutes, which is a minute at one end and about 45 days at the other. All four ship disabled. Set them from your controller.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat does the PLUG-OD-ZW do after a power failure?\u003c\/h3\u003e\n\u003cp\u003eBy default each outlet returns to the state it was in before the power went out. Parameter 6 controls this. Set it to 0 and the outlets stay off when power returns, 1 and they turn on, 2 and they go back to their last state. Setting 2 is the factory default.\u003c\/p\u003e\n\u003cp\u003eYou can change it at the unit with no hub in the room. Press the button ten times to step parameter 6 one value.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat is the difference between the PLUG-OD-ZW and the PLUG-ZW?\u003c\/h3\u003e\n\u003cp\u003eBoth are Versa Z-Wave 800 Long Range plug-in modules on the same radio, and both switch their outlets on and off. The difference is where they go and how many outlets they give you.\u003c\/p\u003e\n\u003cp\u003eThe PLUG-OD-ZW is the outdoor one, and it is a dual outlet outdoor plug: two outlets you can switch separately, under one shared set of load ratings. It has an IP65 enclosure and runs from -4 to 122 deg F.\u003c\/p\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/versawireless.com\/products\/plug-zw\" style=\"color: #1565c0 !important;\"\u003ePLUG-ZW\u003c\/a\u003e is the indoor one, with a single switched outlet in a compact housing for a lamp or an appliance. Pick the PLUG-OD-ZW when the load is outside or when you need two circuits from one device, and the PLUG-ZW when it is a single indoor load.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection class=\"vw-buy\" style=\"margin-top: 32px;\"\u003e\n\u003ch2 id=\"plugodzw-buy-heading\" style=\"font-size: 19px; line-height: 26px; font-weight: 600; margin: 0 0 14px; color: #081f3f !important;\"\u003eWhere to buy the PLUG-OD-ZW\u003c\/h2\u003e\n\u003cul class=\"vw-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealers and distributors:\u003c\/strong\u003e \u003ca href=\"https:\/\/versawireless.com\/pages\/contact-us\" style=\"color: #1565c0 !important;\"\u003econtact Versa\u003c\/a\u003e for stock, lead times and distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealer pricing tiers:\u003c\/strong\u003e \u003ca href=\"https:\/\/versawireless.com\/pages\/wholesale-registration-form\" style=\"color: #1565c0 !important;\"\u003eopen a Versa wholesale account\u003c\/a\u003e for volume pricing across the sensor and Z-Wave line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelated:\u003c\/strong\u003e see the full \u003ca href=\"https:\/\/versawireless.com\/collections\/z-wave\" style=\"color: #1565c0 !important;\"\u003eZ-Wave 800 range\u003c\/a\u003e, or \u003ca href=\"https:\/\/versawireless.com\/pages\/5-free-sensors\" style=\"color: #1565c0 !important;\"\u003erequest 5 free Versa sensors\u003c\/a\u003e for your next install.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Versa Wireless","offers":[{"title":"Default Title","offer_id":48195693281445,"sku":"plug-od-zw","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0524\/5513\/files\/PLUG-OD-ZW1.png?v=1787934989","url":"https:\/\/versawireless.com\/products\/plug-od-zw","provider":"Versa Wireless","version":"1.0","type":"link"}