{"product_id":"plug-zw","title":"PLUG-ZW","description":"\u003cdiv class=\"vw-pdp\"\u003e\n\u003cdiv class=\"vw-tabs\"\u003e\n\u003cinput class=\"vw-tabinput\" type=\"radio\" name=\"vw-tab\" id=\"vw-t1\" checked\u003e \u003cinput class=\"vw-tabinput\" type=\"radio\" name=\"vw-tab\" id=\"vw-t2\"\u003e \u003cinput class=\"vw-tabinput\" type=\"radio\" name=\"vw-tab\" id=\"vw-t3\"\u003e\n\u003cdiv class=\"vw-tabbar\" role=\"tablist\" aria-label=\"Product information\"\u003e\n\u003clabel class=\"vw-tab\" for=\"vw-t1\"\u003eDescription\u003c\/label\u003e \u003clabel class=\"vw-tab\" for=\"vw-t2\"\u003eSpecifications\u003c\/label\u003e \u003clabel class=\"vw-tab\" for=\"vw-t3\"\u003eCompatible Controllers\u003c\/label\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"vw-panel vw-p1\"\u003e\n\u003cp\u003eThe Versa Wireless PLUG-ZW is a \u003cstrong\u003eZ-Wave smart plug\u003c\/strong\u003e built on Z-Wave 800 Series Long Range. It is an indoor plug-in module that adds Z-Wave control to a lamp or a small appliance. It plugs into any grounded 3-wire wall outlet and gives you one switched outlet. Control it from the button on the side of the unit, or from your hub. On Long Range it reaches up to \u003ca href=\"https:\/\/versawireless.com\/blogs\/insight\/z-wave-800-long-range-explained\" style=\"color: #1565c0 !important;\"\u003e1300 ft straight to the controller\u003c\/a\u003e, or 330 ft (100 m) per hop on classic mesh.\u003c\/p\u003e\n\u003cp\u003eIt turns the outlet on and off, so the load question is a rating rather than a curve. The ETL listing rates it at \u003cstrong\u003e15 A general purpose or resistive, 10 A \/ 1250 W tungsten, and a 1\/2 HP motor at 125 VAC\u003c\/strong\u003e. The back of the plug prints the same load classes, so the page and the device use the same words for them. The 1\/2 HP motor rating is what lets it run a fan or a small pump, not only a lamp.\u003c\/p\u003e\n\u003cp\u003ePeople often add a plug-in module because it is always powered and sits mid-house, so it repeats for everything else on a classic mesh. That is true here, with one thing worth knowing before you pair it. \u003cstrong\u003eLong Range is a direct link, and a device added in Long Range mode talks only to the controller.\u003c\/strong\u003e While it is in that mode it repeats for nothing. So the mode you pick at pairing decides which job the plug does. Scan the QR code to a Long Range hub and you get reach. Add it by button to the classic mesh and you get a repeater. One plug does one or the other, not both at once.\u003c\/p\u003e\n\u003cp\u003eSetup is a QR scan. The Z-Wave code on the device carries its DSK, so a SmartStart hub adds it on its own with S2 encryption. Five settings cover the LED, its brightness, auto on and off timers, and what happens after a power cut - see \u003ca href=\"https:\/\/versawireless.com\/blogs\/insight\/z-wave-configuration-parameters-association-groups\" style=\"color: #1565c0 !important;\"\u003eZ-Wave configuration parameters and association groups\u003c\/a\u003e. Full specifications are in the Specifications tab, and the step-by-step is in the \u003ca href=\"https:\/\/versawireless.com\/blogs\/installation-manuals\/plug-zw-installation-manual\" style=\"color: #1565c0 !important;\"\u003ePLUG-ZW installation manual\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 class=\"vw-kf\" style=\"font-size: 17px; line-height: 24px; font-weight: 600; margin: 26px 0 8px; color: #081f3f !important;\"\u003eKey features\u003c\/h2\u003e\n\u003cul class=\"vw-list\"\u003e\n\u003cli\u003eZ-Wave 800 Long Range. Up to 1300 ft direct-to-controller (LR) - 330 ft (100 m) per hop (mesh)\u003c\/li\u003e\n\u003cli\u003ePlug-in on\/off module for lamps and small appliances - no wiring and no wall box\u003c\/li\u003e\n\u003cli\u003e15 A general purpose or resistive, 10 A \/ 1250 W tungsten, 1\/2 HP motor at 125 VAC\u003c\/li\u003e\n\u003cli\u003eOne switched grounded 3-wire outlet, controlled at the button or from your hub\u003c\/li\u003e\n\u003cli\u003eSmartStart pairing with S2 encryption - scan the Z-Wave QR code on the device\u003c\/li\u003e\n\u003cli\u003eAuto turn-off and auto turn-on timers, 1 to 65535 minutes, held at the plug\u003c\/li\u003e\n\u003cli\u003ePower-failure memory - comes back off, on, or to its last state\u003c\/li\u003e\n\u003cli\u003eAdjustable LED brightness, and an LED mode that can follow the outlet, invert, or switch off\u003c\/li\u003e\n\u003cli\u003eBuilt-in repeater - extends a classic mesh for other mains-powered devices\u003c\/li\u003e\n\u003cli\u003eWorks with any Z-Wave certified hub, older or newer generation\u003c\/li\u003e\n\u003cli\u003e2.63 in. x 1.54 in. x 1.14 in. housing\u003c\/li\u003e\n\u003cli\u003eIndoor, US 125 VAC | FCC Part 15 Class B | ETL Listed (c-US) - conforms to UL 60730-1:2016, certified to CSA E60730-1:2015\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"vw-panel vw-p2\"\u003e\n\u003csection class=\"versa-spec-table\"\u003e\n\u003ch2 id=\"plugzw-specs-heading\" style=\"font-size: 19px; line-height: 26px; font-weight: 600; margin: 0 0 14px; color: #081f3f !important;\"\u003ePLUG-ZW Specifications\u003c\/h2\u003e\n\u003cp class=\"versa-spec-sub\"\u003eZ-Wave 800 LR Indoor On\/Off Smart Plug\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003eWireless \u0026amp; Z-Wave\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eProtocol\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\u003cstrong\u003eZ-Wave 800 Series with Long Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e908.42 \/ 916 MHz mesh - 912 \/ 920 MHz LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eRange\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003eUp to 1300 ft direct-to-controller (LR)\u003c\/strong\u003e - 330 ft (100 m) per hop (mesh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSignal Repeater\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eBuilt-in - the plug is always powered, so it repeats for other devices on a classic mesh network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eController Compatibility\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eAny Z-Wave certified controller. Long Range requires an 800 Series controller with Long Range enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eNetwork Interoperability\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eWorks with any Z-Wave certified network. Older and newer Z-Wave devices work together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eZ-Wave Platform\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eZ-Wave 800 Series with Long Range, SDK 7.24.1 - background at the \u003ca href=\"https:\/\/z-wavealliance.org\/\" rel=\"nofollow noopener\" style=\"color: #1565c0 !important;\" target=\"_blank\"\u003eZ-Wave Alliance\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDevice Class\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eGeneric SWITCH BINARY | Specific NOT USED | Role Always On Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDevice IDs\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eManufacturer 0x0464 | Product Type 0xFF00 | Product ID 0xFF0C | Installer Icon 0x0700 | User Icon 0x0704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eVersion\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e1.0 - Z-Wave SDK 7.24.1, Z-Wave version 8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003ePairing \u0026amp; Security\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSmartStart\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eYes - scan the Z-Wave QR code on the device; the QR code carries the DSK, so do not remove or damage it. Long Range needs SmartStart and an LR-enabled hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSecurity\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eS2 security. Use a controller that supports S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eManual Inclusion\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003ePress the button 3x quickly - blue LED flashes, green 2 s = added\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eManual Exclusion\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003ePress the button 3x quickly - purple LED flashes, then green 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eAssociation Group 1\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eLifeline - up to 5 devices, Binary Switch Report. Most controllers set this automatically during inclusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eAssociation Group 2\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eBasic Set - follows the switched outlet's on\/off status, up to 5 devices. This device-to-device path runs on a classic mesh network. In Long Range mode the plug talks to the controller, so build the same behavior as a hub automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFactory Reset\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eClick the button 2x quickly, then hold at least 10 seconds. Removing the plug from your hub also resets it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003ePower \u0026amp; Load\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e125 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eGeneral Purpose \/ Resistive Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e15 A\u003c\/strong\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eTungsten Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003e10 A \/ 1250 W\u003c\/strong\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eMotor Load\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e1\/2 HP max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eOutlet\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e1 switched, grounded 3-wire (NEMA 5-15R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eReceptacle\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003cstrong\u003ePlug directly into a grounded 3-wire receptacle\u003c\/strong\u003e - see the safety note below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003ePower-Fail Restore\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eParameter 6 - 0 = off, 1 = on, 2 = the state prior to the power failure (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFirst Power-Up\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eA plug that has never joined a network powers up with the outlet off and the blue LED on. A plug already on a network returns to its last state and settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003eFunction \u0026amp; Indicators\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDevice Type\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eIndoor plug-in on\/off module (binary switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eButton\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eOn the side of the unit. 1x = outlet on \/ off | 3x = add or remove | 2x then hold 10 s = factory reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eButton Parameter Stepping\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e6x cycles parameter 1 (LED mode) | 8x cycles parameter 7 (LED brightness) | 10x cycles parameter 6 (power-failure state). Each press sequence advances one step, so 0 to 2 takes two sequences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eTimers\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eAuto turn-off and auto turn-on, 1 to 65535 minutes (parameters 2 and 4, disabled by default). Set them from your hub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eLED Mode\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eParameter 1 - 0 = on with the outlet (default), 1 = inverted, 2 = disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eLED Brightness\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eParameter 7 - 0 = bright, 1 = medium, 2 = low (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eConfiguration Parameters\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e5 total - 1, 2, 4, 6, 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eLED Indicator\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eBlue steady = switched outlet on | blue flashing = add in progress | purple flashing = remove in progress | green 2 s = add or remove succeeded | red = network failure. Green flashes twice to confirm a parameter change, three times for the timers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003ePhysical \u0026amp; Operating Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e2.63 in. x 1.54 in. x 1.14 in. (66.8 mm x 39.0 mm x 29.0 mm) housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e32 to 104 deg F (0 to 40 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eUse\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eIndoor - dry locations only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eMarket\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eUS (125 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eOrigin\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eMade in Vietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e2 years from the original date of consumer purchase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"versa-group\" colspan=\"2\" style=\"background-color: #0d1d41 !important; color: #ffffff !important;\"\u003eCertifications \u0026amp; Compliance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eSafety Listing\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003e\n\u003ca href=\"https:\/\/www.intertek.com\/product-certification-marks\/etl\/\" rel=\"nofollow noopener\" style=\"color: #1565c0 !important;\" target=\"_blank\"\u003eETL Listed by Intertek\u003c\/a\u003e, c-US mark - conforms to UL 60730-1:2016 and certified to CSA E60730-1:2015 (automatic electrical controls) | Intertek control no. 5030071\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eFCC\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eFCC Part 15 Class B | FCC ID: 2AD9XPLUG-ZW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"versa-label\"\u003eRF Exposure\u003c\/td\u003e\n\u003ctd class=\"versa-value\"\u003eComplies with FCC uncontrolled-environment limits - install and operate with 20 cm minimum separation from any person\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"versa-foot\"\u003ePlug the unit directly into a grounded 3-wire receptacle. Do not use an extension cord or power strip. Do not exceed 15 A general purpose or resistive, 10 A \/ 1250 W tungsten, or a 1\/2 HP motor. Do not plug in washers, dryers, refrigerators, or motors over 1\/2 HP. Do not use this plug to control medical or life-support equipment, electric heaters, or any appliance that could become hazardous if it operated unattended. Do not include appliance-controlling devices in groups or scenes. Schedules, automations, or network errors may cycle a device unintentionally, so use extreme caution with appliances. Keep the unit away from heat and open flame, and leave the button on the side reachable. Indoor use only, in dry locations. Install per the National Electrical Code (NFPA 70) and local regulations. If unsure, consult a licensed electrician.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"vw-panel vw-p3\"\u003e\n\u003cp\u003eLong Range is where the category is heading: \u003ca href=\"https:\/\/versawireless.com\/blogs\/insight\/z-wave-long-range-adoption-tracker\" style=\"color: #1565c0 !important;\"\u003emost new Z-Wave certifications are Long Range\u003c\/a\u003e. The PLUG-ZW works with any Z-Wave certified controller, so it drops into a Z-Wave smart home network you already run. That includes 2GIG EDGE, Qolsys IQ, SmartThings, Hubitat, Ring Alarm Pro, and Home Assistant with a Z-Wave 800 controller. On a classic mesh network every mains-powered device acts as a repeater, and this plug is one of them.\u003c\/p\u003e\n\u003cp\u003eTo use Long Range, pair it to an 800 Series Long Range controller with SmartStart. Scan the Z-Wave QR code on the device using your controller app. The plug joins on its own with S2 encryption. To join a classic mesh instead, set the controller to add a device and press the button three times quickly.\u003c\/p\u003e\n\u003cp class=\"vw-related\"\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e the PLUG-ZW installation manual ships in the box and is published as a web page: \u003ca href=\"https:\/\/versawireless.com\/blogs\/installation-manuals\/plug-zw-installation-manual\" style=\"color: #1565c0 !important;\"\u003ePLUG-ZW Installation Manual and Setup Guide\u003c\/a\u003e. The rest of the line is in the \u003ca href=\"https:\/\/versawireless.com\/blogs\/installation-manuals\" style=\"color: #1565c0 !important;\"\u003eVersa installation manuals and datasheets\u003c\/a\u003e library. The FCC ID printed on the device is 2AD9XPLUG-ZW. Equipment authorizations are published in the \u003ca href=\"https:\/\/www.fcc.gov\/oet\/ea\/fccid\" rel=\"nofollow noopener\" style=\"color: #1565c0 !important;\" target=\"_blank\"\u003eFCC equipment authorization database\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp class=\"vw-related\"\u003e\u003cstrong\u003eAlso in the Versa Z-Wave 800 line:\u003c\/strong\u003e the \u003ca href=\"https:\/\/versawireless.com\/products\/lamp-zw2\" style=\"color: #1565c0 !important;\"\u003eLAMP-ZW2 plug-in dimmer\u003c\/a\u003e sets a brightness level for a lamp. The \u003ca href=\"https:\/\/versawireless.com\/products\/switch-zw\" style=\"color: #1565c0 !important;\"\u003eSWITCH-ZW in-wall light switch\u003c\/a\u003e and the \u003ca href=\"https:\/\/versawireless.com\/products\/dim-zw\" style=\"color: #1565c0 !important;\"\u003eDIM-ZW in-wall dimmer switch\u003c\/a\u003e cover hardwired circuits.\u003c\/p\u003e\n\u003csection class=\"vw-faq\" style=\"margin-top: 32px;\"\u003e\n\u003ch2 id=\"plugzw-faq-heading\" style=\"font-size: 19px; line-height: 26px; font-weight: 600; margin: 0 0 14px; color: #081f3f !important;\"\u003ePLUG-ZW questions installers ask\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eDoes the PLUG-ZW need a hub?\u003c\/h3\u003e\n\u003cp\u003eYes, for Z-Wave control. The PLUG-ZW is a Z-Wave plug, so a Z-Wave certified controller is what gives you remote control of the outlet. A hub is also what puts it in a scene or runs it on a schedule.\u003c\/p\u003e\n\u003cp\u003eAny Z-Wave certified hub works. Long Range mode needs an 800 Series controller with Long Range switched on.\u003c\/p\u003e\n\u003cp\u003eThe button on the side works with or without a hub. Press it once and the outlet changes state. So the plug still switches a lamp by hand if the network is down.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eHow do I add, pair, or reset the PLUG-ZW?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo add it by QR code:\u003c\/strong\u003e scan the Z-Wave QR code on the device with your controller app, then plug the unit in. It joins on its own with S2 encryption. This is also how it joins in Long Range mode, on an 800 Series controller with Long Range enabled.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo add it by button:\u003c\/strong\u003e set the controller to add a device, then press the button three times quickly. The LED flashes blue, then lights green for two seconds when it is added. This route joins the classic mesh.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo remove it:\u003c\/strong\u003e set the controller to remove a device, then press the button three times quickly. The LED flashes purple, then green for two seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo factory reset it:\u003c\/strong\u003e click the button twice quickly, then hold for at least ten seconds. All custom settings are erased. Use this only if your primary controller is missing or will not respond. Removing the plug from your hub also resets it.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat can I plug into the PLUG-ZW?\u003c\/h3\u003e\n\u003cp\u003eAnything inside its ETL-listed ratings at 125 VAC. That is up to 15 A general purpose or resistive, up to 10 A \/ 1250 W tungsten, and up to a 1\/2 HP motor. The back of the plug prints the same load classes, so the page and the device use the same words for them.\u003c\/p\u003e\n\u003cp\u003eThe motor rating is the one that widens what this plug is for. A 1\/2 HP limit covers a box fan, a small pump, or a workshop tool, alongside the lamps and appliances a smart plug usually runs. The safety note at the foot of the Specifications tab lists the appliances Versa warns against switching remotely. Read it before you pick a circuit.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eDoes the PLUG-ZW work as a Z-Wave repeater?\u003c\/h3\u003e\n\u003cp\u003eOn a classic mesh, yes. The plug is always powered, so it passes traffic for other devices and strengthens coverage around it. That is often the reason to put one halfway down a hallway or in a back bedroom.\u003c\/p\u003e\n\u003cp\u003eThere is a catch worth knowing before you pair it. Long Range is a direct link between the device and the controller. A plug added in Long Range mode talks only to the hub, so it repeats for nothing while it is in that mode.\u003c\/p\u003e\n\u003cp\u003ePick the mode by the job. Scan the QR code to a Long Range hub when you need reach. Add it by button to the classic mesh when you want a repeater.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eHow far does the PLUG-ZW reach on Z-Wave Long Range?\u003c\/h3\u003e\n\u003cp\u003eUp to 1300 ft direct-to-controller on Long Range, and 330 ft (100 m) per hop on classic mesh. The two numbers measure different things. On Long Range the plug talks straight to the hub, so 1300 ft is one direct link with nothing in between. On mesh, 330 ft is the length of a single hop, and the network reaches further by chaining hops through other mains-powered devices.\u003c\/p\u003e\n\u003cp\u003ePick by where the outlet is. A garage, a shop, a barn, or a far corner of a large property is the case Long Range was built for. An outlet inside a house that already has Z-Wave devices is usually better on mesh, because there the plug also repeats for its neighbors.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eCan the PLUG-ZW run a lamp or appliance on a timer?\u003c\/h3\u003e\n\u003cp\u003eYes, and the timer lives in the plug rather than in the hub. Parameter 2 is an auto turn-off delay and parameter 4 is an auto turn-on delay. Both take 1 to 65535 minutes, which is a minute at one end and about 45 days at the other. Both ship disabled.\u003c\/p\u003e\n\u003cp\u003eSet them from your hub. The green LED flashes three times to confirm a timer change.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat does the PLUG-ZW do after a power failure?\u003c\/h3\u003e\n\u003cp\u003eBy default it returns to the state it was in before the power went out. Parameter 6 controls this. Set it to 0 and the outlet stays off when power returns, 1 and it turns on, 2 and it goes back to its last state. Setting 2 is the factory default.\u003c\/p\u003e\n\u003cp\u003eYou can change it at the outlet with no hub in the room. Press the button ten times to step parameter 6 one value. Each press sequence advances one step, so moving from 0 to 2 takes two sequences. The green LED flashes twice when the change saves.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eCan I change or dim the status LED?\u003c\/h3\u003e\n\u003cp\u003eYes, both. Parameter 1 sets what the LED does. Set it to 0 and the LED lights with the outlet, which is the default. Set it to 1 and it inverts, lighting when the outlet is off. Set it to 2 and it stays off.\u003c\/p\u003e\n\u003cp\u003ePress the button six times to step it.\u003c\/p\u003e\n\u003cp\u003eParameter 7 sets how bright it is: 0 is bright, 1 is medium, and 2 is low, which is the default. Press the button eight times to step that one. A low or inverted LED is the usual choice for a bedroom, where a lit plug is the thing people notice at night.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 16px; line-height: 22px; font-weight: 700; margin: 20px 0 6px; color: #081f3f !important;\"\u003eWhat is the difference between the PLUG-ZW and the LAMP-ZW2?\u003c\/h3\u003e\n\u003cp\u003eBoth are Versa Z-Wave 800 Long Range plug-in modules on the same radio. Both go into a grounded indoor outlet and need no wiring work. The difference is what they do to what is plugged in.\u003c\/p\u003e\n\u003cp\u003eThe PLUG-ZW switches the outlet on and off, rated to 15 A general purpose or resistive, 10 A \/ 1250 W tungsten, and a 1\/2 HP motor. That range is what suits an appliance, a fan, or a pump as well as a lamp. \u003c\/p\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/versawireless.com\/products\/lamp-zw2\" style=\"color: #1565c0 !important;\"\u003eLAMP-ZW2\u003c\/a\u003e sets a brightness level instead, for lamps and portable fixtures, and it is the Alarm.com approved device in the Versa Z-Wave line. Pick the PLUG-ZW when the load needs switching, and the LAMP-ZW2 when a lamp needs dimming. For a hardwired circuit, the \u003ca href=\"https:\/\/versawireless.com\/products\/switch-zw\" style=\"color: #1565c0 !important;\"\u003eSWITCH-ZW\u003c\/a\u003e switches and the \u003ca href=\"https:\/\/versawireless.com\/products\/dim-zw\" style=\"color: #1565c0 !important;\"\u003eDIM-ZW\u003c\/a\u003e dims.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003csection class=\"vw-buy\" style=\"margin-top: 32px;\"\u003e\n\u003ch2 id=\"plugzw-buy-heading\" style=\"font-size: 19px; line-height: 26px; font-weight: 600; margin: 0 0 14px; color: #081f3f !important;\"\u003eWhere to buy the PLUG-ZW\u003c\/h2\u003e\n\u003cul class=\"vw-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder direct:\u003c\/strong\u003e the PLUG-ZW is available to order on this page at the listed price.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealers and distributors:\u003c\/strong\u003e \u003ca href=\"https:\/\/versawireless.com\/pages\/contact-us\" style=\"color: #1565c0 !important;\"\u003econtact Versa\u003c\/a\u003e for stock, lead times and distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDealer pricing tiers:\u003c\/strong\u003e \u003ca href=\"https:\/\/versawireless.com\/pages\/wholesale-registration-form\" style=\"color: #1565c0 !important;\"\u003eopen a Versa wholesale account\u003c\/a\u003e for volume pricing across the sensor and Z-Wave line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelated:\u003c\/strong\u003e see the full \u003ca href=\"https:\/\/versawireless.com\/collections\/z-wave\" style=\"color: #1565c0 !important;\"\u003eZ-Wave 800 range\u003c\/a\u003e, or \u003ca href=\"https:\/\/versawireless.com\/pages\/5-free-sensors\" style=\"color: #1565c0 !important;\"\u003erequest 5 free Versa sensors\u003c\/a\u003e for your next install.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Versa Wireless","offers":[{"title":"Default Title","offer_id":48188914630821,"sku":"plug-zw","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0524\/5513\/files\/PLUG-ZW_1.png?v=1787856565","url":"https:\/\/versawireless.com\/products\/plug-zw","provider":"Versa Wireless","version":"1.0","type":"link"}