Installation Manual
LAMP-ZW2 Z-Wave Plug-In Dimmer
The LAMP-ZW2 is a Z-Wave 800 Series Long Range plug-in lamp dimmer that installs in minutes: plug it into a grounded outlet, add it to your Z-Wave controller, and control on/off plus smooth 0-100% dimming.
It runs on 908.42 MHz (US) and pairs with any Z-Wave certified controller, including Alarm.com, 2GIG EDGE, Qolsys IQ, SmartThings, Hubitat, and Home Assistant. Quick start: plug in the dimmer, put your hub in add mode, press the program button 3x quickly (or scan the SmartStart QR code), and assign it to a lamp load of up to 200W incandescent or 100W dimmable LED/CFL.
Wireless
Z-Wave 800 Series with Long Range, 908.42 MHz (US). S2 security, built-in always-on repeater.
Power & load
125 VAC, 60 Hz. Controls up to 200W incandescent/halogen or 100W dimmable LED/CFL.
Use
Indoor, dry locations. Grounded 3-prong plug. ETL Listed to UL 60730-1.
LED indicator
A single status LED on the front of the dimmer reports its state. The normal color is set by parameter 3 (default blue).
| LED state | Meaning |
|---|---|
| Solid (color) | Normal operation - color set by parameter 3 (default blue) |
| Pulsing / flashing | Add mode (inclusion) in progress |
| Solid magenta | Remove mode (exclusion) or error - device is paired; exclude first, then re-add |
Where to plug it in
Plug the LAMP-ZW2 into a grounded 125VAC wall outlet in a dry, indoor location. For best Z-Wave range, avoid metal enclosures and large appliances that can block the signal. Because every mains-powered LAMP-ZW2 is an always-on repeater, placing it between your controller and more distant battery nodes strengthens the whole mesh. If you plan to pair over Z-Wave Long Range, you can locate it far from the hub - LR reaches up to 1,300 ft direct-to-controller line of sight.
Installation steps
Plug in the dimmer
Insert the LAMP-ZW2 into a grounding-type 125VAC outlet. The status LED lights to show the device has power. Plug your lamp or dimmable fixture into the outlet on the front of the module.
Put your controller in add mode
On your Z-Wave hub or panel, open the add-device (inclusion) screen and start the process. Follow your controller's on-screen instructions. Keep the dimmer within range of the hub during pairing; you can move it to its final location afterward.
Add the device
With the controller ready, press the program button on the dimmer 3x quickly. The LED flashes during inclusion. Once paired, the LED returns to solid, and the dimmer appears in your controller for groups, schedules, and automations.
Test on/off and dimming
Press the program button once to toggle the load on and off. Press and hold to dim up or down. Confirm your controller shows the correct on/off state and dim level.
Button functions
The program button on the LAMP-ZW2 handles both everyday control and setup. Every action is a specific press pattern:
| Action | Result |
|---|---|
| Press 1x | Toggle the load on/off (single-tap behavior set by parameter 13) |
| Press and hold | Dim up or down |
| Press 2x quickly | Double-tap action (set by parameter 14, default = night-light) |
| Press 3x quickly | Inclusion / exclusion (add or remove from a network) |
| Press 5x quickly | Set minimum brightness |
| Press 10x quickly | Set maximum brightness |
| Press 8x quickly | Cycle parameter 8 (restore state after power fail) |
| Factory reset | Press 2x quickly, then hold the 3rd press for 10 seconds |
Removing the device (exclusion)
To remove the LAMP-ZW2 from a Z-Wave network, start the remove-device (exclusion) process on your controller, then press the program button 3x quickly. Excluding the dimmer resets its network settings so it can be added to a new controller.
Factory reset
Press the program button 2x quickly, then hold the 3rd press for 10 seconds. Use a factory reset only if the primary controller is missing or inoperable. A solid magenta LED means the device is still paired - exclude it normally first if the controller is available.
Setting minimum and maximum brightness
You can trim the dimming range at the device so the connected bulb never flickers at the bottom or buzzes at the top:
Minimum brightness (param 11)
Press the button 5x quickly - the LED flashes slowly. Hold to set the minimum level, then press 5x to confirm (or wait 10 seconds).
Maximum brightness (param 12)
Press the button 10x quickly - the LED flashes slowly. Hold to set the maximum level, then press 10x to confirm (or wait 10 seconds).
Parameter settings
Configure these from your hub's Z-Wave configuration screen. The LED flashes 3x to confirm a parameter change.
| # | Parameter | Default | Values |
|---|---|---|---|
| 1 | LED Brightness | 1 | 0=100%, 1=60% (def), 2=30% |
| 2 | LED Mode | 0 | 0=on when off (def), 1=on when on, 2=always off, 3=always on |
| 3 | LED Color | 0 | 0=blue (def), 1=green, 2=red, 3=yellow, 4=cyan, 5=magenta |
| 4 | Auto Turn-Off | 0 | Minutes 1-65535. 0=disabled. |
| 6 | Auto Turn-On | 0 | Minutes 1-65535. 0=disabled. |
| 7 | Night Light | 2 | 1-10 = 10-100% brightness |
| 8 | Restore After Power Fail | 2 | 0=off, 1=on, 2=last state (def) |
| 9 | Ramp Rate - Btn ON | 2 | 0=instant, 1-99 sec |
| 10 | Ramp Rate - Hold | 4 | 1-99 sec when held |
| 11 | Min Brightness | 10 | 0=disabled, 1-99% |
| 12 | Max Brightness | 99 | 0=disabled, 1-99% |
| 13 | Single-Tap Brightness | 0 | 0=last (def), 1=Param 15, 2=max, 3=100% |
| 14 | Double-Tap Behavior | 1 | 0=100%, 1=night-light (def), 2=max, 3=disabled |
| 15 | Custom Brightness | 0 | 0=last, 1-99% custom |
| 16 | Local/Z-Wave Lockout | 1 | 0=Z-Wave only, 1=both (def), 2=disable both |
| 17 | Disable Btn Programming | 0 | 0=enabled (def), 1=lock out programming |
| 18 | Ramp Rate - Btn OFF | 2 | 0=instant, 1-99 sec |
| 19 | Ramp Rate - Hub ON | 255 | 1-254 sec; 255=use Param 9 (def) |
| 20 | Ramp Rate - Hub OFF | 255 | 1-254 sec; 255=use Param 18 (def) |
| 21 | LED Confirm Blink | 0 | 0=enabled (def), 1=disabled |
Specifications
| Input | 125 VAC, 60 Hz |
| Protocol | Z-Wave 800 Series with Long Range, S2 security |
| Frequency | 908.42 MHz (US) |
| Range | Up to 1,300 ft direct-to-controller line of sight (Z-Wave Long Range) |
| Incandescent / halogen load | 200 W max |
| Dimmable CFL / LED load | 100 W max |
| Repeater | Built-in always-on Z-Wave Plus repeater |
| Power connection | Grounded 3-prong (Type B); grounding-type outlet required |
| Power-loss memory | Restores on/off state after a power cycle (parameter 8) |
| Use | Indoor, dry location |
| Listing | ETL Listed by Intertek - UL 60730-1:2016 |
| FCC ID | 2AD9XLAMP-ZW2 (FCC Part 15 Class B) |
| Z-Wave Alliance | Z-Wave Plus certified - Product #5062 |
| Firmware | V8.10.00 (SDK 7.24.1) |
Compatible controllers and panels
The LAMP-ZW2 works with any Z-Wave certified controller, and all non-battery Z-Wave nodes act as repeaters regardless of vendor. Versa officially lists the following as compatible: Alarm.com, 2GIG EDGE, Qolsys IQ, SmartThings, Hubitat, and Home Assistant (with a Z-Wave 800 controller). The dimmer is officially Alarm.com approved, so dealers can add it to an Alarm.com account and control it natively - no secondary app or workaround. It is backward compatible with Z-Wave 500, 700, and Plus networks. To use Z-Wave Long Range, pair it to an 800 Series Long Range controller via SmartStart; see the LAMP-ZW2 setup guide and Z-Wave 800 Long Range explained for details. Z-Wave Plus certification is verified through the Z-Wave Alliance (Product #5062).
Association groups
- Group 1 - Lifeline: Binary Switch Report and Device Reset Locally. Group 1 must be assigned to the primary controller's Node ID; most controllers configure this automatically.
- Group 2 - Basic Set ON/OFF: sends a Basic Set command triggered by the local button, so pressing the dimmer can control associated devices directly.
Z-Wave 800 Long Range plug-in dimmer, officially Alarm.com approved.
Download the printable manual
The full LAMP-ZW2 installation manual is available as a printable PDF with the specifications, LED indicator table, button functions, network setup, and parameter reference.
Frequently asked questions
How do I add the LAMP-ZW2 to my Z-Wave controller?
Plug the dimmer into a grounded 125VAC outlet, start the add-device (inclusion) process on your controller, then press the program button 3x quickly - the LED flashes during inclusion. Or scan the SmartStart DSK QR code on the back of the dimmer with a SmartStart-capable controller and it adds automatically within 10 minutes.
Is the LAMP-ZW2 the best Z-Wave 800 Long Range plug-in lamp dimmer for Alarm.com?
The LAMP-ZW2 is a Z-Wave 800 Series Long Range plug-in dimmer that is officially Alarm.com approved, so dealers can control it natively on an Alarm.com account. It reaches up to 1,300 ft direct-to-controller line of sight and dims up to 200W incandescent or 100W LED/CFL.
What load can the LAMP-ZW2 control?
Up to 200W incandescent or halogen, and 100W dimmable CFL or LED, with smooth 0-100% dimming. Input is 125VAC, 60Hz through a grounded 3-prong plug, for indoor dry-location use only.
How do I factory reset the LAMP-ZW2?
Press the program button 2x quickly, then hold the 3rd press for 10 seconds. Use a factory reset only if the primary controller is missing or inoperable; otherwise exclude the device normally from your controller.
What frequency does the LAMP-ZW2 use, and which controllers is it compatible with?
It operates on 908.42 MHz (US) Z-Wave and works with any Z-Wave certified controller. Versa officially lists Alarm.com, 2GIG EDGE, Qolsys IQ, SmartThings, Hubitat, and Home Assistant, and it is backward compatible with Z-Wave 500, 700, and Plus networks.
Does the LAMP-ZW2 act as a Z-Wave repeater?
Yes. Because it is mains powered, the LAMP-ZW2 has a built-in always-on Z-Wave Plus repeater that strengthens the mesh for every non-battery node on the network, regardless of vendor.
How do I set the dimming range on the LAMP-ZW2?
Set minimum brightness by pressing the button 5x quickly, holding to the desired level, then pressing 5x to confirm (parameter 11). Set maximum brightness by pressing 10x quickly, holding, then pressing 10x to confirm (parameter 12). Both can also be configured from your hub.
FCC ID: 2AD9XLAMP-ZW2. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment; install and operate with a minimum distance of 20 cm between the radiator and any person. ETL Listed by Intertek to UL 60730-1:2016. Z-Wave Plus certified (Z-Wave Alliance Product #5062). versawireless.com