Skip to content
MINI-345 Installation Manual & Setup Guide

Installation manual - 345 MHz door and window contact

MINI-345 Installation Manual

Mount, enroll and service the MINI-345 on Honeywell VISTA and Lyric, 2GIG and Resideo PROA7 panels. Same body as the 5800MINI, programs on Loop 1.

Document V0000558-01-01, MINI-345 Installation Instructions, the revision this page follows. Applies to every MINI-345 with the slide-off cover.

First page of the MINI-345 Installation Manual PDFInstallation & Setup Guide
PDF - V0000558-01-01
Frequency345 MHzHoneywell VISTA and Lyric, 2GIG, PROA7 with the PROTAKEOVER
Replaces5800MINI drop-insame 2.2 x 1 x 0.25 in. body, same zone type
Battery5+ yearsone Panasonic CR2032 coin cell
Magnet gap1 in. / 1/4 in.maximum on wood / on metal
Install LEDBluefieldblue LED confirms the magnet is in range
LoopLoop 1magnetic contact on every supported panel

01Overview

What this manual covers

The Versa Wireless MINI-345 is a single-zone 345 MHz door and window transmitter. It sends on the Honeywell and Resideo 5800-series protocol, so it enrolls on a Honeywell VISTA with a 5800-series receiver and on a Honeywell Lyric. It also enrolls on 2GIG GC2, GC3, EDGE and GC Touch panels, because they read 5800-series sensors natively. A Resideo PROA7 or PROA7PLUS hears it through a PROTAKEOVER module set to rotary 0.

If you've installed a 5800MINI, you already know this sensor. The body is the same 2.2 x 1 x 0.25 in. and it mounts in the same spot. It programs as the same kind of zone, with the magnetic contact on Loop 1. What's different is the cover, which slides off instead of prying off. The blue Bluefield LED is new too, and it tells you the magnet is in range while you're still holding the parts to the frame.

This page runs through the job in the order you'd do it. We start with placement, then the battery and the tape, then enrollment on each panel family. After that come the LED legend, battery service and the full spec table. The PDF button above is the same manual, document V0000558-01-01, if you'd rather have it in the truck.

Before you start

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212 deg F (100 deg C), or incinerate. Dispose of used batteries properly. Keep away from children. Use of another battery may present a risk of fire or explosion.

Worth knowing

On a Resideo PROA7 or PROA7PLUS the PROTAKEOVER module has to be fitted first. Set it to rotary position 0, the 5800 position, or the panel won't hear the MINI-345. The module handles one legacy protocol at a time, so check the rotary before you start enrolling.

02In the box

What ships with the MINI-345

  • The MINI-345 transmitter, which is 2.2 x 1 x 0.25 in. and ships in white, and the Panasonic CR2032 coin cell that runs it.
  • The magnet, a neodymium rare-earth piece 1 in. long in a housing 0.320 in. wide, which is the part that goes on the door or the sash.
  • Double-faced tape, so both pieces mount to a clean frame without a drill or a screw.
  • A slide-off cover, which means you get at the battery with your thumb and the sensor stays on the frame. Brown and black cover packs are sold separately.

03Placement

Where to mount the MINI-345

Put the transmitter on the part that stays still, which is the frame. The magnet goes on the part that moves, which is the door or the opening sash. Mount on the frame or the casing, not on the glass. Keep the two pieces lined up along the long edge, so the reed sits in the magnet's field when the opening is shut.

Metal is the thing that shortens your gap. On wood you've got up to 1 in. between the magnet and the transmitter. On a steel door, an aluminum window frame or metal casing you plan on 1/4 in., because the surface pulls the field away from the reed. Foil-backed wallpaper does the same thing, so treat it as metal.

Keep it dry and keep it inside the temperature range, which is 32 to 122 deg F (0 to 50 deg C). Furnace rooms and utility rooms are poor spots, because the metal and the wiring in them soak up signal. Before you commit the tape anywhere, run the panel's Go/No Go test from the mounting spot. That test is the only check of radio signal you've got.

Mounting cautions: Verify adequate signal strength by using the control panel's Go/No Go test (see control's instructions) before mounting permanently. Keep the Mini-345 and magnet away from metal or metallic surfaces such as foil wallpaper. Avoid mounting the Mini-345 in areas with a large quantity of metal or electrical wiring, such as a furnace or utility room.

04Install

Fit the battery, then mount the sensor and the magnet

  1. Slide the cover open

    Push the cover along the body and it slides off in your hand, so there's no tab to pry and nothing to break.

  2. Fit the battery plus side up

    Seat the Panasonic CR2032 with the plus side facing up, then slide the cover back on. The blue and green LEDs come on and stay live for 15 minutes.

  3. Mount the transmitter on the frame

    Press it onto the frame of the protected door or window with the double-faced tape, after you've run the Go/No Go test from that spot.

  4. Mount the magnet and check the blue LED

    Stick the magnet on the door, or on the opening part of the window, then close it. The blue LED lights when the magnet is in range, and that's your placement check.

If the blue LED stays dark with the opening closed, the magnet is out of range. Move it closer, or line it up with the transmitter's edge, before you press the tape down hard. If the LEDs have timed out, slide the cover off and they run for another 15 minutes.

05Enroll

Add the MINI-345 to the panel

The MINI-345 has a unique serial number built in, and the panel learns it from the first transmission it hears while it's in autolearn. So the sequence is the same on every 345 MHz panel: start autolearn, open and close the magnet once, then set the zone on Loop 1 and save. Our panel-by-panel install guide has the exact key sequence for each one, and here's the shape of it.

Honeywell VISTA with a 5800-series receiver

  1. Check the signal first. From the keypad, the RF sniffer is Installer Code + [#] + [3] and the Go/No Go test is Installer Code + [#] + [4]. Exit with the Installer Code + OFF.
  2. Open zone programming. In installer programming, start *56 zone programming and pick the zone number.
  3. Learn the serial. When the panel asks for the serial number, open and close the magnet, and the panel reads it from the transmission. Confirm it, and set the loop to 1.
  4. Finish the zone. Set the zone type, usually perimeter, then save and test the zone from the keypad.

Honeywell Lyric

  1. No receiver to add. The Lyric has its 345 MHz receiver built in, so you go straight to the installer tools and choose to add a sensor.
  2. Trip the sensor. Open and close the magnet once, and the panel fills in the serial number.
  3. Set Loop 1 and the zone type, name the zone, then save and walk-test it.

2GIG GC2, GC3, EDGE and GC Touch

  1. Open the installer toolbox and go to wireless zones, then pick the next free zone.
  2. Learn the serial. Choose learn, then open and close the magnet, and the panel reads the serial number from the transmission.
  3. Set Loop 1, pick the sensor type and the equipment code for a door or window contact, name the zone and save.

Resideo PROA7 and PROA7PLUS

  1. Fit the PROTAKEOVER and set its rotary to 0, the 5800 position. The panel's own PROSiX receiver stays live alongside it.
  2. Add a sensor from the installer tools, then open and close the magnet so the panel learns the serial number.
  3. Set Loop 1 and the zone type, name the zone, then save and test it.
Honeywell VISTA (5800-series receiver)Honeywell Lyric2GIG GC2 / GC3 / EDGE / GC TouchResideo PROA7 / PROA7PLUS PROTAKEOVER, rotary 0

The green LED tells you the sensor transmitted, and it doesn't tell you the panel heard it. So after you've added the zone, open and close the door a couple of times and watch the panel register each change before you leave the job.

06LEDs

What the lights mean

Three LEDs, and the blue and green ones are install tools on a 15 minute timer.

LED What it tells you When it runs
Blue Lights when the magnet is within proper range of the MINI-345, which is 1 in. maximum. This is the Bluefield magnet indicator. Active for 15 minutes after the battery is first installed or when the cover is removed
Green Flashes when the MINI-345 transmits Active for 15 minutes after the battery is first installed or when the cover is removed
Red Low battery Flashes once about every five seconds for two minutes after a transmission

To wake the blue and green LEDs on a sensor that's already mounted, slide the cover off and the 15 minute window starts again. That's how you re-check magnet placement months later without touching the panel.

07Battery

Replace the battery

One Panasonic CR2032 runs the MINI-345 for 5+ years in typical use, and it's the same cell the 5800MINI took. When it gets low, the red LED flashes once about every five seconds for two minutes after each transmission. Your panel reports a low battery on that zone at the same time, and the swap takes a minute with the sensor still on the frame.

  1. Vertically slide open the cover and lift out the old battery.
  2. Fit a fresh Panasonic CR2032 with the plus side up, because that's the only cell the MINI-345 is specified for.
  3. Slide the cover back on. The blue and green LEDs run for 15 minutes, so you can confirm the magnet is still in range while you're there.

Battery rating

Battery: 3VDC, 225mAh, Lithium Coin Cell; Panasonic CR2032

Use of another battery may present a risk of fire or explosion.

BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212 deg F (100 deg C), or incinerate. Dispose of used batteries properly. Keep away from children. Use of another battery may present a risk of fire or explosion.

08Specifications

MINI-345 specifications

Every MINI-345 figure in one place, the same numbers you'll find on the product page.

Wireless and RF
Frequency 345 MHz (Honeywell / Resideo 5800-series protocol)
Panel compatibility Honeywell VISTA series (5800-series receiver) - Honeywell Lyric (receiver built in) - 2GIG GC2 / GC3 / EDGE / GC Touch - Resideo PROA7 / PROA7PLUS (PROTAKEOVER set to rotary 0)
Loop number Loop 1 (magnetic contact input)
Enrollment Built-in serial number, learned in auto-learn mode on a supervised zone
Detection and function
Device type Single-zone door and window transmitter
Bluefield magnet indicator Patented - the blue LED lights when the magnet is within proper range, 1 in. maximum
LED indicators Blue (magnet in range), green (transmit), red (low battery)
Install LED window Blue and green active for 15 minutes after battery installation or cover removal; remove the cover to restart
Low-battery signal Red LED flashes once about every five seconds for two minutes after a transmission
Reed and tamper Internal reed switch; tamper trips on cover removal
Magnet gap (maximum) 1 in. (25.4 mm) on wood, 1/4 in. (6.35 mm) on metal
Magnet type Neodymium rare earth
Physical
Transmitter dimensions 2.2 x 1 x 0.25 in. (55.9 x 25.4 x 6.4 mm), the same body as the 5800MINI
Magnet width 0.320 in., 38 percent narrower than the 5800MINI's 0.520 in.; 1 in. long
Mounting Surface mount on the frame, double-faced tape supplied
Enclosure Slide-off cover; white as shipped, with brown and black cover packs sold separately
Power
Battery 3VDC, 225mAh, Lithium Coin Cell; Panasonic CR2032, fitted plus side up
Battery life 5+ years typical
Environmental
Operating conditions 32 to 122 deg F (0 to 50 deg C)
Relative humidity Relative Humidity 95%, (non-condensing); UL Tested at 85%
Use Indoor, away from moisture
Certifications and warranty
Regulatory listings UL 639 / UL 1023, ULC-S304 / C1023
Radio compliance FCC Part 15 and ISED licence-exempt RSS
Document V0000558-01-01 MINI-345 Installation Instructions
Warranty 2 years from the original date of consumer purchase

Mount the transmitter on the door or window frame, not on the glass. Keep both pieces clear of metal, foil wallpaper, moisture and rooms full of electrical wiring. Refer to the installation instructions for the control panel this device is used with for the limitations of the whole alarm system.

09Troubleshooting

When something doesn't look right

The calls we get most on the MINI-345, and what's usually behind them.

What you see What's going on What to do
The blue LED won't light on a sensor that's been mounted a while The install LEDs timed out after 15 minutes Slide the cover off to restart the window, then close the opening and read the LED
The blue LED is dark with the door closed, cover just removed The magnet is out of range or off the long edge Move the magnet closer, within 1 in. on wood or 1/4 in. on metal, and line it up with the transmitter
A PROA7 never shows the sensor when you learn it The PROTAKEOVER is missing or on the wrong rotary Fit the module and set the rotary to 0, then open and close the magnet again
The zone shows a fault after you replaced a 5816 The loop number carried over from the old part Set the MINI-345 zone to Loop 1 and re-test
The zone drops out or shows a weak signal Metal, wiring or distance between the sensor and the panel Run the Go/No Go test and move the sensor off metal casing or out of the utility room
The red LED flashes after each transmission The battery is low Fit a fresh Panasonic CR2032, plus side up

Still stuck? Contact Versa Wireless with the panel model and what the LEDs are doing, and we'll sort it out with you.

10FAQ

MINI-345 installation questions

What frequency does the MINI-345 use, and which panels is it compatible with?

The MINI-345 transmits at 345 MHz on the Honeywell and Resideo 5800-series protocol. That means Honeywell VISTA with a 5800-series receiver, and Honeywell Lyric, which has one built in. It also means 2GIG GC2, GC3, EDGE and GC Touch, which read 5800-series sensors natively.

A Resideo PROA7 or PROA7PLUS hears it through a PROTAKEOVER module set to rotary 0, and on every one of them the contact programs on Loop 1.

How do I enroll the MINI-345 into my panel?

Put the panel in autolearn, or its add-sensor mode, then open and close the magnet once. The sensor sends its built-in serial number, the panel reads it, and you set the zone type on Loop 1 and save.

Run the panel's Go/No Go test from the mounting spot before you press the tape down, because the green LED only tells you the sensor transmitted. Our panel-by-panel install guide has the key sequence for a VISTA-20P, a Lyric, a PROA7 and a 2GIG EDGE.

Does the MINI-345 work with 2GIG panels as well as Honeywell?

Yes, and that's the point of it. The MINI-345 sends on the 5800-series protocol at 345 MHz, and 2GIG GC2, GC3, EDGE and GC Touch read 5800-series sensors natively.

So the same part enrolls on a VISTA, a Lyric, a GC3 or an EDGE, and you stock one sensor instead of two.

What does the blue LED on the MINI-345 mean?

The blue Bluefield LED lights when the magnet is within proper range of the transmitter, which is 1 in. maximum. So you set the magnet, close the door and read the answer at the opening instead of walking back to the keypad.

It runs for 15 minutes after you fit the battery or take the cover off, and sliding the cover off again restarts it.

What battery does the MINI-345 use and how do I replace it?

One 3VDC 225 mAh Panasonic CR2032 lithium coin cell, rated for 5+ years. The red LED tells you when it's low, flashing once about every five seconds for two minutes after a transmission.

To replace it, slide the cover open, lift out the old cell, fit the fresh CR2032 plus side up and slide the cover back on. The sensor stays on the frame the whole time.

What is the maximum magnet gap for the MINI-345?

Up to 1 in. on wood and up to 1/4 in. on metal surfaces. Metal pulls the magnet's field, so steel doors, aluminum frames and foil wallpaper all get the tighter figure.

Let the blue LED confirm the gap with the door or window closed before you finish the install, and run the Go/No Go test for signal.

Is the MINI-345 a direct replacement for the Resideo 5800MINI?

Yes. It runs on the same 345 MHz frequency, fits the same panels, and has the same 2.2 x 1 x 0.25 in. body. So you mount it where the old one was, and you program it as the same kind of zone on Loop 1. The magnet housing is narrower, 0.320 in. against the 5800MINI's 0.520 in., so it fits tighter channels too.

The 5800MINIV that Resideo sells in the 5800MINI's place is 2.44 x 1.25 x 0.45 in. and runs on a CR2450. Our 5800MINI replacement guide walks through a swap.

Which loop number does the MINI-345 use?

Loop 1, on every panel it supports. That's the magnetic contact input, and you set it when you program the zone after the panel has learned the serial number.

If you're replacing a 5816 that was used as a plain door contact, check the loop, because a 5816's reed input is Loop 2 on that part. The 5816 alternative guide covers that swap, including the wired-loop case the MINI-345 doesn't take on.

Why did the blue and green LEDs stop lighting?

They're on an install timer. Both run for 15 minutes after the battery goes in or the cover comes off, and then they turn off to save the cell.

Slide the cover off and you get another 15 minutes, which is all you need to re-check the magnet on a sensor that's already mounted.

Which Versa contact do I use on a 319.5 MHz or 433 MHz panel?

The same sensor comes in three radio bands, so you pick by the panel. Go with the MINI-319 for Qolsys IQ panels with the 319.5 MHz SRF card and for GE/Interlogix-class panels. The MINI-433 is the one for a DSC PowerSeries PC1832 or PC1864, Impassa or Alexor.

All three share the housing, the Bluefield LED, the slide-off cover and the CR2032. You'll find them side by side in the door and window sensors collection.

Need it on the truck? The file is the same document, with the figures.

Download the manual (PDF)Installation & Setup Guide - V0000558-01-01 - 2 pages - 1.4 MB

Regulatory

FEDERAL COMMUNICATIONS COMMISSION STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User Manual.

Unauthorized changes or modifications could void the user's authority to operate the equipment.

FCC/IC STATEMENT

This device complies with Part 15 of the FCC Rules, and Industry Canada's license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation.

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.

The French-language ISED statement is printed in the PDF manual.

Cart 0

Your cart is currently empty.

Start Shopping