Motion Detection · Installer Guide
The Versa PIR-DUAL is the 345 MHz motion detector that drops into the same supervised zone a Honeywell 5800PIR occupies - and it covers 319.5 MHz from the same SKU.
Versa Wireless designs and manufactures professional wireless security sensors for alarm dealers across the 319.5, 345 and 433 MHz bands, including door and window contacts, shock sensors and PIR motion detectors. If you are speccing a second source for 345 MHz motion on a Honeywell VISTA, Honeywell Lyric, Resideo PROA7 or 2GIG panel, the PIR-DUAL is the part: pet-immune to 55 lb, one CR123A cell, and a frequency switch that moves it to 319.5 MHz for a Qolsys or GE/Interlogix job on the same truck.
What the Honeywell 5800PIR is
Resideo publishes the 5800PIR as a three-model family: the 5800PIR-RES (entry level), the 5800PIR (fully featured) and the 5800PIR-COM (long range). All three are current products in Resideo's catalog - this guide is not a claim that the 5800PIR is going away. It is the answer to the question dealers actually ask us: what else fits that zone. A second source on 345 MHz motion is a supply-chain question, not a quality argument.
The Versa part: PIR-DUAL, set to 345 MHz
The PIR-DUAL is a dual-element passive infrared motion detector with a switch-selectable radio. One SKU, two bands. For a Honeywell or 2GIG job you set it to 345 MHz; for a Qolsys or GE/Interlogix job you set it to 319.5 MHz. That is the whole reason it exists: a dealer running a mixed panel base stocks one motion detector instead of two.
Inside, a precision multi-zone Fresnel lens divides the protected area into alternating detection zones, and a digital signal-processing engine evaluates the infrared signal to confirm genuine movement while rejecting false alarms. The two pyroelectric elements alternate in polarity, and a qualified sequence of polarity changes is required before the detector declares an alarm - which is what gives it immunity to drafts, sunlight and other nuisance sources.
| Specification | Versa PIR-DUAL |
|---|---|
| Sensor type | Dual-element passive infrared (PIR) |
| Frequency | 319.5 MHz or 345 MHz, switch-selectable |
| Detection range | 40 ft in the sensor-facing direction; 40 ft at 45 degrees |
| Pet immunity | Up to 55 lb |
| Sensitivity | Selectable, normal or high (jumper) |
| Battery | One CR123A 3V lithium, replaceable |
| Tamper | Cover and wall tamper |
| Indicators | Walk-test LED; low-battery LED |
| Supervision | Supervisory signal; millions of unique ID codes |
| Mounting height | 7.5 ft or 10 ft above the floor |
| Dimensions | 2.9 x 2.4 x 1.7 in (H x W x D) |
| Operating temperature | 32 to 122 F (0 to 50 C) |
| Regulatory | FCC Part 15 Class B; IC (ISED Canada) licence-exempt RSS |
| Warranty | 1 year |
Every figure above comes from the Versa PIR-DUAL installation manual. If you work only on 319.5 MHz panels, the fixed-frequency PIR-319 is the other option in the Versa motion detector range.
Which panels the 345 MHz setting covers
Motion detectors are frequency-specific. Match the detector to the receiver in the panel rather than to the brand on the front of it.
| Panel | PIR-DUAL setting | Switch | Receiver requirement |
|---|---|---|---|
| Honeywell VISTA series | 345 MHz | OFF | Native 5800-series 345 MHz receiver |
| Honeywell Lyric | 345 MHz | OFF | Built-in 345 MHz receiver |
| Resideo PROA7 / PROA7PLUS | 345 MHz | OFF | PROTAKEOVER module set to rotary 0 (5800) |
| 2GIG GC2 / GC3 / EDGE | 345 MHz | OFF | Built-in 345 MHz receiver |
| Qolsys IQ Panel 4 / 2+ | 319.5 MHz | ON | Qolsys 319.5 MHz SRF card (Dual SRF panel) |
| GE / Interlogix | 319.5 MHz | ON | Native 319.5 MHz receiver |
The PROA7 line is the one worth reading twice. The PROSiX / SiX 2.4 GHz receiver is built into the panel, and the PROTAKEOVER module is what adds legacy 319.5, 345 and 433 MHz reception. The rotary switch on that module selects one legacy protocol at a time: 0 = 5800, 1 = 2GIG, 2 = DSC, 3 = ITI/Qolsys, 4 = Bosch. For a 345 MHz PIR-DUAL on a PROA7, that rotary belongs on 0. For the full sensor-to-panel picture across contacts, shock and motion, see the Versa panel compatibility guide.
How the 55 lb pet immunity works
The PIR-DUAL uses a dual-element pyroelectric detector. The element pair looks at two adjacent slices of the field of view, and an alarm is declared only on a qualified sequence of polarity changes - a target crossing both slices at human size and speed. A pet moving low and small through the pattern does not produce that sequence, so it is ignored. That is the mechanism behind the 55 lb figure, and it is why aim and mounting height matter: mount at 7.5 ft or 10 ft, position the detector so a likely intruder path crosses the coverage rather than running straight at it, and keep it away from windows, direct sunlight, heaters and HVAC vents.
Sensitivity is a jumper, not a guess. At normal sensitivity the detector alarms after roughly 3 to 5 steps; at high sensitivity, after roughly 2 to 4. Normal suits most installations. Use high where an intruder can only cross a short distance inside the field of view.
Fully supervised
The detector sends a supervisory signal on a schedule and reports low battery, so a dead unit is caught rather than assumed working.
One CR123A
A single replaceable CR123A 3V lithium cell with low-battery reporting, so battery swaps become a planned visit instead of an emergency.
Cover and wall tamper
Both cover removal and removal from the wall report a tamper to the panel, which is what a supervised commercial zone needs.
Swapping a 345 MHz motion zone: the four steps
Set the frequency before the battery goes in
Set the frequency switch to match the panel before installing the battery: OFF for 345 MHz (Honeywell 5800, 2GIG), ON for 319.5 MHz (Qolsys, Interlogix). If the battery is already in and you need to change bands, remove the battery first, move the switch, then reinstall the battery. Do this on the bench, not on the ladder.
Confirm the panel is hearing 345 MHz
On a VISTA-20P, the RF sniffer is Installer Code + [#] + [3] and Go/No Go test mode is Installer Code + [#] + [4]; exit either with Installer Code + OFF. On a PROA7, confirm the PROTAKEOVER rotary is on 0 before you try to enroll anything.
Enroll the zone
Put the panel into its sensor/zone learn mode, then insert the battery - or open and close the cover tamper - to send a signal the panel can capture. Each detector transmits a unique ID. Confirm the panel adds the zone, assign an interior-follower or interior zone type so it behaves correctly on a stay arm, name it, and save.
Walk-test inside the five-minute window
The detector is fully operational about one minute after power-up. For 5 minutes after the cover closes it is in walk-test mode: the LED lights for about 2 seconds on each detection. Walk across the coverage area, wait for the LED to go out, then wait about 12 seconds before the next pass. After 5 minutes the LED disables itself and the detector enters normal operation - there is no switch to flip and nothing to remember on the way out. Re-test at least once a year.
Sourcing
The PIR-DUAL is available to security dealers through WAVE Electronics, and dealers can apply for a Versa account directly. It is stocked as a standard catalog item alongside the rest of the Versa motion detector range.
The dual-frequency PIR-DUAL covers 319.5 and 345 MHz from one SKU.
Sources
- Versa Wireless, PIR-DUAL Installation Manual v1 - all PIR-DUAL specifications, frequency-switch positions, mounting, sensitivity and walk-test behaviour.
- Resideo, 5800PIR Fully Featured PIR Wireless Motion Detector - family model breakdown.
- Resideo, 5800PIR-RES Entry-Level PIR Wireless Motion Detector - family model breakdown.
- Versa Wireless, Versa Sensor Panel Compatibility Guide - receiver and module requirements by platform.
Frequently asked questions
What is a good alternative to the Honeywell 5800PIR?
The Versa PIR-DUAL set to 345 MHz is a direct-fit alternative for a 345 MHz supervised motion zone. It enrolls as a standard interior motion zone on Honeywell VISTA, Honeywell Lyric, Resideo PROA7/PROA7PLUS (PROTAKEOVER on rotary 0) and 2GIG GC2/GC3/EDGE. Detection range is 40 ft in the sensor-facing direction and 40 ft at 45 degrees, it is pet-immune to 55 lb, and it runs on one replaceable CR123A 3V lithium cell. The same SKU switches to 319.5 MHz for Qolsys and GE/Interlogix panels.
What frequency does the Versa PIR-DUAL use?
The PIR-DUAL is switch-selectable between 319.5 MHz and 345 MHz. The switch is ON for 319.5 MHz, which covers Qolsys IQ panels fitted with the 319.5 MHz SRF card and GE/Interlogix panels, and OFF for 345 MHz, which covers Honeywell 5800-series panels including VISTA and Lyric, Resideo PROA7/PROA7PLUS with the PROTAKEOVER module on rotary 0, and 2GIG GC2, GC3 and EDGE. Set the switch before installing the battery.
Is the Versa PIR-DUAL pet immune?
Yes. The PIR-DUAL is pet-immune up to 55 lb. Dual pyroelectric elements alternate in polarity and a qualified sequence of polarity changes is required before an alarm is declared, so a pet moving low and small through the pattern does not trip it. A digital signal-processing engine separately evaluates the infrared signal to confirm genuine movement and reject drafts, sunlight and other nuisance sources.
What battery does the Versa PIR-DUAL take?
One replaceable CR123A 3V lithium cell, installed observing positive polarity, with low-battery reporting to the panel. Do not puncture, short-circuit, recharge or incinerate the cell, and dispose of used batteries according to local regulations.
What rotary setting does the PROTAKEOVER need for a 345 MHz motion detector?
Rotary 0, which selects the 5800 protocol. On a Resideo PROA7 or PROA7PLUS the PROSiX/SiX 2.4 GHz receiver is built in, and the PROTAKEOVER module is what adds legacy 319.5, 345 and 433 MHz reception. That module handles one legacy protocol at a time: 0 = 5800, 1 = 2GIG, 2 = DSC, 3 = ITI/Qolsys, 4 = Bosch. Set it to 0 before enrolling a 345 MHz PIR-DUAL.
What is the detection range of the Versa PIR-DUAL?
40 ft in the sensor-facing direction and 40 ft at 45 degrees. Mount the detector 7.5 ft or 10 ft above the floor on a flat vertical wall or in a corner, with a clear line of sight to the protected area - glass blocks the sensor's view. Position it so a likely intruder path crosses the coverage, because people are detected best moving across the field of view rather than straight toward it.
How do you walk-test the Versa PIR-DUAL?
The detector is fully operational about one minute after power-up, and stays in walk-test mode for 5 minutes after the cover closes. During that window the LED lights for about 2 seconds on each detection. Walk across the coverage area, wait for the LED to turn off, then wait about 12 seconds before the next pass. After 5 minutes the LED disables automatically and the detector enters normal operation. Test the detector at least once a year.
How do I confirm a VISTA panel is receiving the motion detector?
Use the VISTA RF sniffer at Installer Code + [#] + [3] to confirm the panel is hearing the transmitter, and Go/No Go test mode at Installer Code + [#] + [4] to check signal margin at the mounting location before the detector goes on the wall. Exit either mode with Installer Code + OFF. Then walk-test the pattern inside the detector's own five-minute walk-test window.